PI-LAB-2024-093
Thymosin Alpha-1, Independent Lab Report
Thymosin Alpha-1 5mg · Sterling Compound Co.
Independent testing verdict Pass
This product matched its label.
Identity confirmed and measured purity of 98% met the stated ≥98% claim. Content measured 100.4% of label.
- Identity verified
- Yes
- Measured purity
- 98.0%
- Content accuracy
- 100.4%
- Test recency
- Older result
Mass spectrometry confirmed the labelled compound
Label claimed ≥98%
5.02mg measured against 5mg claimed
Published 24 months ago
Specimen PI-LAB-2024-093 Tested by Cornerstone Analytical 14 samples tested from this company Purity & Testing score 91/100
Full laboratory evidence Findings table, methodology, chain of custody and the original report
Findings
| Metric | Label claim | Measured | Assessment |
|---|---|---|---|
| Purity (HPLC) | ≥ 98% | 98% | Meets claim |
| Identity (MS) | Thymosin Alpha-1 | Confirmed | Matches label |
| Content | 5 mg | 5.02 mg | Within 5% of label |
Methodology & chain of custody
RP-HPLC purity with electrospray ionisation mass confirmation.
The sample was purchased anonymously through standard retail checkout and shipped to an unaffiliated address, then logged, photographed, and forwarded under chain-of-custody documentation to Cornerstone Analytical. See our full testing methodology.
- Lot / batch
- B5174-24
- Purchased
- Analysed
- Published
- Laboratory
- Cornerstone Analytical
- Test type
- Content verification
Original laboratory report: PI-LAB-2024-093-report.pdf