Independent testing verdict Pass
This product matched its label.
Identity confirmed and measured purity of 93.5% met the stated ≥95% claim. Content measured 100.8% of label.
- Identity verified
- Yes
- Measured purity
- 93.5%
- Content accuracy
- 100.8%
- Test recency
- Older result
Mass spectrometry confirmed the labelled compound
Label claimed ≥95%
36.27mg measured against 36mg claimed
Published 23 months ago
Specimen PI-LAB-2024-106 Tested by Vantage Analytical Labs 12 samples tested from this company Purity & Testing score 89/100
Full laboratory evidence Findings table, methodology, chain of custody and the original report
Findings
| Metric | Label claim | Measured | Assessment |
|---|---|---|---|
| Purity (HPLC) | ≥ 95% | 93.5% | Within analytical tolerance |
| Identity (MS) | Orforglipron | Confirmed | Matches label |
| Content | 36 mg | 36.27 mg | Within 5% of label |
Methodology & chain of custody
RP-HPLC purity with electrospray ionisation mass confirmation.
The sample was purchased anonymously through standard retail checkout and shipped to an unaffiliated address, then logged, photographed, and forwarded under chain-of-custody documentation to Vantage Analytical Labs. See our full testing methodology.
- Lot / batch
- A5463-24
- Purchased
- Analysed
- Published
- Laboratory
- Vantage Analytical Labs
- Test type
- Purity & identity
Original laboratory report: PI-LAB-2024-106-report.pdf