PI-LAB-2026-110

Semaglutide, Independent Lab Report

Semaglutide 10mg · Cascade Research Group

Discrepancy

Independent testing verdict Discrepancy

This product was authentic but did not match its label.

Identity confirmed, but measured purity of 96.1% fell short of the stated ≥99% claim.

Identity verified
Yes

Mass spectrometry confirmed the labelled compound

Measured purity
96.1%

Label claimed ≥99%

Content accuracy
98.6%

9.86mg measured against 10mg claimed

Test recency
Current cycle

Published 2 months ago

Specimen PI-LAB-2026-110 Tested by Vantage Analytical Labs 9 samples tested from this company Purity & Testing score 9/100

Full laboratory evidence Findings table, methodology, chain of custody and the original report

Findings

Metric Label claim Measured Assessment
Purity (HPLC) ≥ 99% 96.1% Materially below claim
Identity (MS) Semaglutide Confirmed Matches label
Content 10 mg 9.86 mg Within 5% of label

Methodology & chain of custody

RP-HPLC purity with electrospray ionisation mass confirmation.

The sample was purchased anonymously through standard retail checkout and shipped to an unaffiliated address, then logged, photographed, and forwarded under chain-of-custody documentation to Vantage Analytical Labs. See our full testing methodology.

Lot / batch
R3881-26
Purchased
Analysed
Published
Laboratory
Vantage Analytical Labs
Test type
Purity & identity

Testing notes

Company was notified before publication and given the standard dispute window.

Original laboratory report: PI-LAB-2026-110-report.pdf (document delivery arrives with the production storage backend)

More Tests, Cascade Research Group

Semaglutide
Purity 58.1% Failed
BPC-157
Purity 61.0% Failed
BPC-157
Purity 64.3% Failed

More Tests, Semaglutide

Semaglutide Verity Research Chemicals
Purity 96.8% Verified
Semaglutide Apex Peptides
Purity 99.1% Verified
Semaglutide Cascade Research Group
Purity 58.1% Failed