Independent testing verdict Pass
This product matched its label.
Identity confirmed and measured purity of 98.4% met the stated ≥98% claim. Content measured 98.4% of label.
- Identity verified
- Yes
- Measured purity
- 98.4%
- Content accuracy
- 98.5%
- Test recency
- Current cycle
Mass spectrometry confirmed the labelled compound
Label claimed ≥98%
1.97mg measured against 2mg claimed
Published 9 months ago
Specimen PI-LAB-2026-131 Tested by Cornerstone Analytical 15 samples tested from this company Purity & Testing score 99/100
Full laboratory evidence Findings table, methodology, chain of custody and the original report
Findings
| Metric | Label claim | Measured | Assessment |
|---|---|---|---|
| Purity (HPLC) | ≥ 98% | 98.4% | Meets claim |
| Identity (MS) | Gonadorelin | Confirmed | Matches label |
| Content | 2 mg | 1.97 mg | Within 5% of label |
Methodology & chain of custody
RP-HPLC purity with electrospray ionisation mass confirmation.
The sample was purchased anonymously through standard retail checkout and shipped to an unaffiliated address, then logged, photographed, and forwarded under chain-of-custody documentation to Cornerstone Analytical. See our full testing methodology.
- Lot / batch
- A6179-26
- Purchased
- Analysed
- Published
- Laboratory
- Cornerstone Analytical
- Test type
- Full panel (purity, identity, content, endotoxin)
Original laboratory report: PI-LAB-2026-131-report.pdf